LANGUAGE: 

EN  DE

LANGUAGE: 

EN  DE


FLOWMETERS & INDICATORS FOR WATER & OTHER LIQUIDS

FLOWMETERS & DISPLAYS FOR WATER & OTHER LIQUIDS

i FOR  MORE INFORMATION ON THE PRODUCT CLICK ON THE CORRESPONDING PRODUCT NAME

i FOR  MORE INFORMATION ON THE PRODUCT CLICK ON THE CORRESPONDING PRODUCT NAME

OR GO DIRECTLY TO OUR SELECTION TOOL

ELEKTRICAL MEASURING PRINCIPLES

TYPE SERIES
 


MEASURING RANGE (L/MIN)


MAX. PRESSURE
(BAR)


TEMPERATURE
(°C)


INDUSTRIES
 


FROM

TO

FROM

TO

MIN.         MAX.

WATERTREATMENT


POWERGENERATION


MACHINERY&PLANTCONSTRUCTION


PROCESSENGINEERING


WATER

TREATMENT


POWER

GENERATION


MACHINERY

CONSTRUCTION


PROCESS

ENGINEERING


0,5

80

for fluids
(0,5 - 80 l/min)

max. operating pressure:

PN  25 bar

operating temperature:

from -20°C to 100°C

25

-20

100

✓

✓

✓

✓

0,0083

250

for fluids
(0,5 - 250 l/min)

max. operating pressure:

PN  16 bar

operating temperature:

from 5°C to 90°C
(optional 0°C)

16

-20

90

✓

✓

✓

✓

MECHANICAL MEASURING PRINCIPLES

TYPE SERIES
 


MEASURING RANGE (L/MIN)


MAX. PRESSURE
(BAR)


TEMPERATURE
(°C)


INDUSTRIES
 


FROM

TO

FROM

TO

MIN.         MAX.

WATERTREATMENT


POWERGENERATION


MACHINERY&PLANTCONSTRUCTION


PROCESSENGINEERING


WATER

TREATMENT


POWER

GENERATION


MACHINERY

CONSTRUCTION


PROCESS

ENGINEERING



for fluids
(0,1 - 50 l/min)

max. operating pressure:

PN 10 bar

operating temperature:

from -20°C to 100°C
(optional -20°C to 160°C)

0,1

50


.

10


-20

100


✓

✓

✓

✓


0,2

250

for fluids
(0,2 - 250 l/min)

max. operating pressure:

PN 10 bar

operating temperature:

from -20°C to 100°C

(optional -20°C to 160°C)

.

10

-20

100

✓

✓

✓

✓


8

150

for fluids

(8 - 150 l/min)

max. operating pressure:
PN 10 bar

operating temperature:
from -20°C to 100°C

(optional -20°C to 160°C)

.

10

-20

100

✓

✓

✓

✓


0,2

28

for fluids
(0,2 - 28 l/min)

max. operating pressure:
PN 16 bar

operating temperature:
from -20°C to 100°C

(optional -20°C to 160°C)

.

16

-20

100

✓

✓

✓

✓


0,005

5

.

16

for fluids
(0,005 - 5 l/min)

max. operating pressure:
PN 16 bar

operating temperature:
from -20°C to 100°C

(optional -20°C to 160°C)

-20

100

✓

✓

✓

✓


for fluids

(0,001 - 17 l/min)

for gaseous media

(0,02 - 500 Nl/min)

max. operating pressure:
PN 15 bar

operating temperature:
from -20°C to 80°C

 

0,001

17

.

15

-20

80

✓

X

X

✓


0,04

833

for fluids

(0,04 - 833 l/min)

for gaseous media
(0,67 - 25000 Nl/min)

max. operating pressure:
PN 5 bar / PN 15 bar (optional)

operating temperature:
from -20°C to 80°C

5

15

-20

80

✓

X

X

✓



for fluids 

(0,1 - 50 l/min)

max. operating pressure:

PN 100 bar (brass lead-free) 

PN 300 bar (stainless steel)

operating temperature:

from -20°C to 100°C
(optional -20°C to 160°C)

0,1

50

100

300

-20

100

✓

✓

✓

✓



0,1

50

for fluids
(0,1 - 50 l/min)

max. operating pressure:

PN 100 bar (brass lead-free) 

PN 300 bar (stainless steel)

operating temperature:

from -20°C to 100°C
(optional -20°C to 160°C)

100

300

-20

100

✓

✓

✓

✓



for fluids
(0,2 - 250 l/min)

max. operating pressure:

PN 100 bar (brass lead-free) 

PN 300 bar (stainless steel)

operating temperature:

from -20°C to 100°C
(optional -20°C to 160°C)

0,2

250

100

300

-20

100

✓

✓

✓

✓



for fluids
(0,2 - 250 l/min)

max. operating pressure:

PN 100 bar (brass lead-free) 

PN 300 bar (stainless steel)

operating temperature:

from -20°C to 100°C

(optional -20°C to 160°C)

0,2

250

100

300

-20

100

✓

✓

✓

✓



for fluids

(0,007 - 17 l/min)

for gaseous media
(0,2 - 500 Nl/min)

max. operating pressure:

PN 16 bar (with NV) 

PN 40 bar (without NV)

operating temperature:

from -20°C ro 200°C
(optional -80°C ro 250°C)

0,07

17

16

40

-80

200

✓

✓

✓

✓




for fluids (133 - 333 l/min)

max. operating pressure:
PN 180 bar

operating temperature:
from -20°C to 100°C

(optional -20°C to 160°C)

80

260

180

-20

100

✓

✓

✓

✓


for fluids

(10 - 150 l/min)

max. operating pressure:

PN 100 bar (brass lead-free) 

PN 300 bar (stainless steel)

operating temperature:

from -20°C to 100°C

(optional -20°C to 160°C)

10

150

100

300

-20

100

✓

✓

✓

✓



for fluids
(0,02 - 30 l/min)

max. operating pressure:

PN 100 bar (brass lead-free) 

PN 350 bar (stainless steel)

operating temperature:

from -20°C to 100°C
(optional -20°C to 160°C)

0,02

30

100

350

-20

100

✓

✓

✓

✓



for fluids

(0,005 - 5 l/min)

max. operating pressure:

PN 160 bar (brass lead-free) 

PN 350 bar (stainless steel)

operating temperature:

from -20°C to 100°C
(optional -20°C to 160°C)

0,005

5

160

350

-20

100

✓

✓

✓

✓


10

150

for fluids

(10 - 150 l/min)

max. operating pressure:
PN 100 bar (brass lead-free) 

PN 300 bar (stainless steel)

operating temperature:
from -20°C to 100°C

(optional -20°C to 160°C)

100

300

-20

100

✓

✓

✓

✓


0,02

30

160

350

-20

100

✓

✓

✓

✓

For fluids

(0,02 - 30 l/min)

max. operating pressure:
PN 160 bar (brass lead-free) 

PN 350 bar (stainless steel)

operating temperature:
from -20°C to 100°C

(optional -20°C to 160°C)

250

300


for fluids (0,005 - 5 l/min)

max. operating pressure:
PN 16 bar (brass lead-free)

operating temperature:
from -20°C to 100°C

0,005

5


16

-20

100

X

✓

✓

✓


0,7

20

for fluids (0,7- 20 l/min)

max. operating pressure:
PN 100 bar (brass lead-free) 

PN 300 bar (stainless steel)

operating temperature:
from -20°C to 120°C

(optional -20°C to 160°C)

100

300

-20

120


✓

✓

✓

✓


for fluids
(2,5 - 15,5 l/min)

max. operating pressure:
PN 100 bar (brass lead-free)

operating temperature:
from -20°C to 100°C
(optional -20°C to 160°C)

2,5

15,5


100

-20

100

X

✓

✓

✓


for fluids
(0,4 - 15,5 l/min)

max. operating pressure:
PN 100 bar (brass lead-free)

operating temperature:
from -20°C to 100°C
(optional -20°C to 160°C)

0,4

15,5

100

-20

100

X

✓

✓

✓


for fluids
(0,04 - 3000 l/min)

for gaseous media

(1,17 - 90000 Nl/min)

max. operating pressure:
PN 10 bar / PN 16 bar / PN 40 bar

operating temperature:
from -50°C to 300°C
 

0,05

3.000

16

40

-50

300

✓

✓

✓

✓


for fluids

(0,167 - 1000 l/min)

for gaseous media

(on request)

max. operating pressure:
PN 10 bar / PN 16 bar / PN 40 bar

Operating Temperature:
from -50°C to 300°C 

0,2

1.000

16

40

-50

300

✓

✓

✓

✓


for fluids

(2,5 - 100 l/min)

max. operating pressure:
PN 10 bar

operating temperature:
from 0°C to 100°C

 

2,5

100

10

-20

100

✓

✓

✓

✓



for fluid media
(0,025 - 1,67 l/min)

for gaseous media
(1,67 - 500 Nl/min)

max. operating pressure:
PN 10 bar

operating temperature:
from 0°C to 60°C
(optional 0°C to 100°C)

0,03

17

10

0

100

✓

X

✓

X



for fluids 
(0,2 - 1000 l/min)

for gaseous media
(25 - 14.000 Nl/min)

max. operating pressure:
PN 10 bar

operating temperature:
from 0°C to 60°C
(optional 0°C to 100°C)

0,8

1.000

10

0

60

✓

X

✓

X


for fluids

(0,025 - 1,67 l/min)

max. operating pressure:  

PN 6 bar/ PN 10 bar (optional)

operating temperature:

from 0°C to 60°C

10

0,025

1,67

6

10

0

60

✓

X

✓

X


for fluids

(0,025 - 1,67 l/min)

max. operating pressure:
PN 10 bar

operating temperature:

from 0°C to 80°C 

10

0,025

1,67

10

0

80

✓

X

✓

X


0,025

1,67

for fluids

(0,025 - 1,67 l/min)

max. operating pressure:
PN 10 bar

operating temperature:

from 0°C to 60°C 

10

0

60

✓

X

✓

X





0,8

16,7

for fluids 

(0,83 - 16,7 l/min)

max. operating pressure:
PN 6 bar

operating temperature:

from 0°C to 80°C 

10

6

0

80

✓

X

✓

X


for fluids

(0,83 - 16,7 l/min)

max. operating pressure:
PN 6 bar

operationg temperature:

from 0°C to 60°C

0,8

16,7

6

0

60

✓

X

✓

X



4

1,178

for fluids

(0,15 - 10 m/s)

max. operating pressure:
PN 10 bar

operating temperature:

from 0°C to 80°C 

10

0

80

✓

X

✓

X



for fluids

(1 - 60 l/min)

max. operating pressure:

PN  10 bar

operating temperature:

from -20°C to 90°C

1

60

5

10

0

90

✓

✓

✓

✓


0,7

100

16

0

100

for fluids
(0,7 - 100 l/min)

max. operating pressure:

PN  16 bar

operating temperature:

from -20°C to 100°C

✓

✓

✓

✓



for fluids

(2 - 40 l/min)

max. operating pressure:
PN 10 bar

operating temperature:
from 0°C to 85°C 

2

40

10

0

85

✓

X

✓

X



for fluids

(4 - 160 l/min)

max. operating pressure:
PN 10 bar

operating temperature:
from 0°C to 80°C 

4

160

10

0

80

X

X

✓

X



for fluid media
(7 - 417 l/min)

max. operation pressure:

PN 10 bar

operating temperature:

from 0°C to 85°C
 

4

160

10

0

85

✓

✓

✓

✓



7

417

for fluids (7 - 417 l/min)

max. operating pressure:
PN 10 bar

operating temperature:
from 0°C to 85°C 

10

-40

85

X

✓

✓

✓



for fluids

(2,3 - 2762 l/min)

max. operating pressure:
PN 11 bar (brass) / PN 30 bar (stainless steel)

operating temperature:
from -40°C to 120°C 

2,3

2.762

30

-20

20

X

✓

✓

✓


4

93

25

for fluids

(4 - 93 l/min)

max. operating pressure:
PN 25 bar

operating temperature:
from -20°C to 110°C

-20

110

X

✓

✓

✓


for fluids

(3,5 - 69 l/min)

max. operating pressure:
PN 25 bar

operating temperature:
from -20°C to 110°C 

3,5

69

25

-20

110

✓

✓

✓

✓



for fluids
(13,3 - 13333 l/min)

max. operating pressure:

PN  16 bar / PN 40 bar

operating temperature:

von -20°C bis 130°C

(optional -20°C bis 300°C)

13,3

13.333

40

-20

300

✓

✓

✓

✓